Thermal bridges in renovation: recognising and preventing them

Published: 29 October 2026.

A new extension or a better-insulated roof can greatly improve comfort. Yet one cold detail can cause problems: a thermal bridge. It is particularly important to consider the complete construction detail where new work connects to an existing wall, floor or roof. What is a thermal bridge, how can you recognise it, and which decisions should you make before work starts?

What is a thermal bridge?

A thermal bridge, also called a cold bridge, is a point where heat flows out through the structure more easily than through the surrounding areas. This can happen where insulation is interrupted, a material conducts heat well, or two building elements meet in an unfavourable way. The inside surface can become colder at that point. If the indoor air contains enough moisture, condensation can form on the cold surface, increasing the risk of mould.

A thermal bridge is not the same as an air leak. A gap can cause draughts and allow warm air to escape, whereas a thermal bridge involves heat flowing through the structure. Both can occur at the same junction. A leak or rising damp can also cause a wet patch. Have the cause investigated before choosing a solution.

Where do thermal bridges occur during renovation?

In a complete renovation, extension or roof addition, these junctions deserve particular attention:

  • A new extension to an existing home: the junction between the new floor, existing wall, foundation and roof edge.
  • A roof addition or replacement roof: the connection between roof insulation and the existing wall, and around roof openings.
  • Windows and doors: frames, reveals, sills and lintels where the insulation layer may be interrupted.
  • Structural elements: a steel beam, concrete balcony slab or floor that passes through the insulated building envelope.
  • Internal insulation: joist ends and other timber elements that may become colder or damper after insulation is installed.

Not every detail carries the same risk. The existing structure, material choices, insulation and ventilation together determine the appropriate solution.

How can you spot a possible thermal bridge?

A locally cold wall, condensation, recurring mould or a dark patch near a corner or window frame may be a sign. However, a photograph or a hand on the wall cannot reliably establish the cause. Check whether the patch is linked to rain, cold weather, cooking or showering. A building surveyor can assess the structure and moisture behaviour and take targeted measurements if needed. Thermal imaging can help, provided conditions are suitable and the results are interpreted correctly.

Removing mould alone is not enough if the cause remains in the structure or ventilation. Where moisture problems already exist, a new internal lining wall can even make matters worse if the construction has not been investigated beforehand.

How can thermal bridges be prevented in design and construction?

The best time to prevent a thermal bridge is before the finishes are applied. The design should show how the insulation layer continues at floors, walls, roofs, window frames and structural penetrations. Discuss where a thermal break or a different construction detail is needed. Coordinate materials, airtightness and moisture behaviour; adding insulation to just one surface is not always enough.

During construction, junctions and dimensions are at least as important as the chosen insulation value. Before details are covered, check that insulation is continuous, joints are finished according to the plan and the structural solution is correct. Record critical details with photographs. If a complex detail is in doubt, a specialist can carry out calculations or assess its building physics.

What if condensation or mould is already present?

Start with the cause: is it a thermal bridge, inadequate ventilation, an air leak or moisture from outside? Several causes can occur together. Provide sufficient ventilation and address leaks or damp, but also have the construction detail assessed. It can then be determined whether insulation repairs, a better junction, airtightness measures or another intervention are needed. The right solution differs from one home to another.

Checklist for your renovation or extension

  • Have the existing walls, floors, roof and window frames been surveyed?
  • Are all junctions between old and new clearly shown on the drawings?
  • Where is the insulation layer continuous, and where is it interrupted?
  • Have steel or concrete elements and timber joist ends been assessed separately?
  • Is there a plan for ventilation, airtightness and moisture control?
  • Who will check the critical details before they are covered?

Also read our building survey checklist and our guide to choosing materials for an extension or renovation.

Would you like to discuss your renovation plans?

For a larger renovation or home extension, design, structural engineering and construction belong together. Ponto Services can help you identify existing details that need attention and incorporate them into the renovation plan. Explore our options for home extensions or renovation, or discuss your plans.

Sources consulted on 29 October 2026: Milieu Centraal on thermal bridges and moisture in internal lining walls; IPLO on insulation and airtightness in renovations; Dutch government guidance on ventilation.